Quickview
Multi Power Power Range: 15-240 kW + redundancy 25-400 kW + redundancy 42-1008 kW + redundancy
MODULAR TYPE UPS, RIELLO(MPW and MPX) is a three-phase uninterruptible power supply with a modular architecture, ON LINE Double Conversion type, with the possibility of redundant. It delivers a rated power from 15 to 1176 kW and it is manufactured using specially-designed components and transformerless technologies that deliver exceptional efficiency up to 96.5%, and high power density in a compact footprint. Modularity reduces the risk of wasteful oversizing at installation, while offering “pay as you grow” scalability when it’s time to expand, optimising initial investment and total cost of ownership (TCO). It is designed to protect: - any critical high-density computer and IT environment - data centers - critical loads -
Quickview
Multi Power2 Power Range: 500 – 1600 kVA
THREE PHASE UPSMulti Power2 is the evolution of our modular UPS, which aims to offer higher power density, simpler integration to both existing and new installations, and last but not least, enhanced operating efficiency and global flexibility to reduce both the upfront investment and the day-to-day operational costs. Thanks to its modular architecture, the system can be adapted to the load demands to avoid any oversizing and provide the best performance in every working condition. With a new extremely high-density power module, available in two different models, Multi Power2 reaches up to 1600 kW in a single UPS and up to 6400 kW with 4 systems in parallel. -
Quickview
Multi Sentry (MST) Power Range: 60 – 200 kVAMulti Sentry (MST) Power Range: 60 – 200 kVA
RIELLO, THREE PHASE UPSA transformerless UPS offering you high efficiency in a compact footprint, the Multi Sentry is a superb solution for sites that have limited power, loads that generate harmonic currents, or where the UPS is supported with a generator. Choose from 6 power ratings to suit your power needs. Designed to power capacitive loads like blade servers without any reduction in active power. Range of battery cabinet sizes depending on your runtime requirements. -
Quickview
NORTEC
LINDNERThe raised access floor system NORTEC is the ideal product for nearly all applications with its excellent technical and building-physical characteristics. The raised access floor panels consist of fibre-reinforced calcium sulphate optionally applied with a steel sheet on the lower side. The panels are protected against shock and humidity by an edge trim on all edges. The substructure consists of height-adjustable zinc-coated steel pedestals from our own production which form the necessary cavity for installations and gaskets for sound decoupling. -
Quickview
ORTEA
ORTEAFounded in 1969, ORTEA SpA is a leading company in manufacturing and engineering voltage stabilizers, magnetic components, electrical equipment, and as from 2014 automatic power factor correction systems. -
Quickview
Sentinel Dual (SDH) Power Range: 1 – 3KVA
RIELLO, SINGLE PHASE UPSSentinel Dual is the new range of high density double conversion online UPS, suitable for powering a wide range of devices such as servers, storage systems, telephony - VoIP equipment, network and medical systems as well as industrial applications. It is also ideal for powering and protecting Blade Server systems with high input power factor. At only 2U, Sentinel Dual is ideal for 19” rack cabinet installations. Sentinel Dual has a practical, modern design and includes several performance advantages over traditional ON LINE UPS. The newly-designed inverter is one of the best energy conversion systems on the market, with a 0.9 output power factor and 92% operating efficiency in ON LINE Mode. For business continuity applications requiring long battery runtimes, battery autonomy can be extended up to several hours using ER models fitted with more powerful battery chargers. With energy savings in mind, Sentinel Dual is also fitted with a shut-off button to reduce energy consumption to zero during prolonged periods of inactivity. -
Quickview
Sentinel Dual (SDU) Power Range: 4 – 10KVA
RIELLO, SINGLE PHASE UPSSentinel Dual is the best solution for powering mission critical applications and electro-medical devices requiring maximum power reliability. Flexibility of installation and use (digital display, user-replaceable battery set), as well as the many communication options available, makes the Sentinel Dual suitable for many different applications from IT tosecurity. Up to 3 Sentinel Duals can be operated in parallel in either capacity or N+1 redundant configuration offering increased reliabilit y for critical system. The Sentinel Dual can be installed as Tower (floor standing) or Rack, ideal for network and server rack applications. -
Quickview
Sentinel Tower (STW) Power Range: 6 – 10KVA
RIELLO, SINGLE PHASE UPSSentinel Tower is the ideal solution for protecting mission critical systems such as safety devices, telecommunications equipment but also IT systems to ensure maximum power reliability. Sentinel Tower is designed and built using state-of-the-art technology and components to provide maximum protection to the powered loads with no impact on downstream systems and optimised energy savings. The series includes 5-6 kVA single/singlephase and 8-10 kVA single/three-phase input single phase output models with on-line double conversion technology (VFI): the load is powered continuously by the inverter which supplies a sinusoidal voltage, EMERGENCY filtered and stabilised in terms of form and frequency. -
Quickview
Sentryum (S3T) Power Range: 10 – 40KVA
RIELLO, THREE PHASE UPSThe rapid evolution of IT technologies, augmented focus on environmental matters and complexity of critical applications are demanding more flexible, efficient, secure and interconnected power protection solutions. The Sentryum 10-40 kVA/kW offers the best combination of power availability, energy efficiency and global performance ensuring installation and running cost savings. It is the very latest Riello UPS development resulting in a third- generation transformer-free UPS, originally introduced into the market over twenty years ago. This ultimate solution is rated at output power factor 1 and defined as ON LINE double conversion technology in accordance with VFI-SS-111 classification (as set out in standard IEC EN 62040-3).